Comparison of IEC, European (CENELEC) and British Standards

3 min read

Prior to UK entry into the European Union, electrical equipment for hazardous area was manufactured to British Standard BS 4683. Equipment built and certified to this standard would display the mark ‘EX’ on the label, which indicated that the equipment was explosion protected (do not confuse with explosion-proof, which is entirely different).
In addition, the label was also marked with a ‘crown’ symbol, which was the distinctive mark for the UK test house BASEEFA.

Because of the differences in standards, UK equipment could not be used in the other European countries, and vice-versa.

European co-operation resulted in the development of harmonised standards, know as “Euronorms”, for which the first English version was published as BS5501. The second generation of the UK version, which replaced this, carried the Euronorm numbering in the EN 500—series. Equipment marking for EN500—was ‘EEx’.

International Standards are now identical to the Euronorms, and carry numbers in the IEC60079 series. The identical European standards carry the EN60079-1. The marking for equipment manufactured to IEC/EN60079 standards is ‘Ex’.

The latest (at March 2015) standards are:

IECGas/ DustEuronorms
IEC NumberDatedConstructional standards (Type of Protection)Latest EN
(H = Harmonized EN)
Old EN number
IEC 60079-0 Ed 62011-06General RequirementG & DEN 60079-0:2012 H50 014
IEC 60079-1 Ed 72014-06Flameproof EnclosureGEN 60079-1:2007 H50 018
IEC 60079-2 Ed 62014-07Pressurised Equipment ‘p’GEN 60079-2:2007 H50 016
IEC 60079-5 Ed 42015-02Power Filling ‘q’GEN 60079-5:2007 H50 017
IEC 60079-6 Ed 42015-02Oil Immersion ‘o’GEN 60079-6:2007 H50 015
IEC 60079-7 Ed 52015-06Increased Safety ‘e’GEN 60079-7:2007 H50 019
IEC 60079-11 Ed 62011-06Intrinsic Safety ‘I’G & DEN 60079-11:2012 H50 020
IEC 60079-13 Ed 12010-10Pressurised room ‘p’G  
IEC 60079-15 Ed 42010-01Type of Protection ‘n’GEN 60079-15:2010 H50 021
IEC 60079-16 Ed 11990-05Artificial ventilation for analyser housesG  
IEC 60079-18 Ed 42014-12Encapsulation ‘m’G & DEN 60079-18:2009 H50 028
IEC 60079-25 Ed 22010-02Intrinsic safety electrical systems ‘I’G & DEN 60079-25:2010 H50 039
IEC 60079-26 Ed 32014-06Equipment with Equipment Protection Level ‘Ga”GEN 60079-26:2007 H 
IEC 60079-27 Ed 22008-01Fieldbus intrinsically safe concept (FISCO) is now included in 60079-11GEN 60079-27:2008 H 
IEC 60079-28 Ed 22015-02Protection of optical radiation systemGEN 60079-28:2007 H 
IEC 60079-29-1,2,3,42007-15Gas detector EN 60079-29:2007 H EN 60079-29: 2010 H 
IEC 60079-30 1&2, Ed 12007-01Electrical trace heating EN 60079-30-1:2007 H 
IEC 60079-31 Ed 22013-11Equipment dust ignition protection by enclosure ‘tD’DEN 60079-31:2014 H 
IEC 60079-32 1&2, Ed 12013-08 2015-02Electrostatic hazard   
IEC 60079-33 Ed 12012-09Special protection ‘s’   
IEC 60079-35 1&2, Ed 12011-05 2011-12Caplights for use in mines EN 60079-35-1:2011 
  “Codes of Practice”   
60079-10-1 Ed 12008-12Classification of hazardous areas – gasesG  
60079-10-2 Ed 22015-01Classification of hazardous areas – dustsD  
60079-14 Ed 52013-11Electrical installation in hazardous areasG & D  
60079-17 Ed 52013-11Inspection and maintenance of equipment in hazardous areasG & D  
60079-19 Ed 3+Am12015-03Repair and overhaulG & D  
60079-20-1 Ed 12010-01Data for flammable gasesGEN 60079-20-1:2010 H 

The EU ATEX Directives are now in force in Europe and the certification authorities are known as Notified Bodies (NB). Each has their own unique NB number, which will be marked on the certification labels of ATEX approved equipment and systems.

Notified Bodies in the UK include Baseefa Ltd (NB Number 1180), SIRA Certification Service (NB 0518), and ITS Testing and Certification (NB 0359).

Some of the European Notified Bodies are shown on the map:

map of notified European bodies