The equipment marking must be to IEC 60079-2 & IEC 60079-0, and contain the following information:

  1. The manufacturers name
  2. Model number, type and serial number
  3. The symbol Ex, followed by the pressurisation types i.e. pxb, pyb, or pzc
  4. The gas group symbol II, temperature class, or the maximum surface temperature, or both, e.g. T3, or 200°C, or 200°C (T3)
  5. The certificate number
  6. The internal free volume excluding the ducts
  7. The protective gas (when a gas other than air is used)
  8. Details of the minimum purge requirements
  9. The minimum and maximum permissible over-pressure
  10. The minimum flow of protective gas
  11. The min. and max. supply pressure to the system
  12. The maximum leakage rate from the enclosure
  13. The temperature or temperature range of the safe gas at the inlet duct
  14. The point(s) where the pressurisation is to be monitored.

IEC 60079-17:2013 Table 3

Inspection schedule for Ex “p” and Ex “pD” installations

Check that :Grade of
inspection
X = required   
AEQUIPMENTDCV
1Equipment is appropriate to the EPL/Zone requirements of the locationXXX
2Equipment gas group is correctXX 
3Equipment temperature class or surface temperature is correctXX 
4Equipment circuit identification is correctX  
5Equipment circuit identification is availableXXX
6Enclosure, glasses and glass-to-metal sealing gaskets and/or compounds are satisfactoryXX 
7There are no unauthorised modificationsX  
8There is no evidence of unauthorised modifications XX
9Lamp type, rating and position are correctX  
BInstallation   
1Type of cable is appropriateX  
2There is no obvious damage to the cableXXX
3Earthing connections, including any supplementary earthing bonding connections, are satisfactory, for example connections are tight and conductors are of sufficient cross-sectionXXX
 Physical checkXXX
 Visual checkXXX
4Fault loop impedance (TN systems) or earthing resistance (IT systems) is satisfactoryX  
5Automatic electrical protective devices operate within permitted limitsX  
6Automatic electrical protective devices are set correctlyX  
7Protective gas inlet temperature is below maximum specifiedX  
8Ducts, pipes and enclosures are in good conditionXXX
9Protective gas is substantially free from contaminantsXXX
10Protective gas pressure and/or flow is adequateXXx
11Protective and/or flow indicators, alarms and interlocks function correctlyX  
12Conditions of spark and particle barriers of ducts for exhausting the gas in hazardous area are satisfactoryX  
13Specific conditions of use (if applicable) are complied withX  
CENVIRONMENT   
1Equipment is adequately protected against corrosion, weather, vibration and other adverse factorsXXX
2No undue accumulation of dust and dirtXXX
(D=detailed, C=close, V=visual)